The High-Precision Automatic Calibration Unit is designed for fast and accurate calibration of battery charge-discharge testing equipment. It uses high-precision measurement instrumentation to automatically calibrate voltage and current channels across a wide operating range, helping maintain measurement accuracy and consistency throughout battery testing operations.
The system supports voltage calibration from 0V to 2000V and current calibration from 0A to 1500A. It can automatically match the calibration range of the connected equipment and complete calibration of each channel in ≤2 minutes, significantly reducing manual calibration time.
系统功能
关键系统参数
Parameters | |
|---|---|
Calibration Range | Voltage: OV to 2000V |
Calibration Time per Channel | ≤2 mins /CH |
Digital Multimeter | 6.5 digital DMM from Top-tier International Brand |
Calibration Accuracy | 0.01% F.S (Hall Sensor or Current Shunt) |
Functions | |
|---|---|
Automatic Calibration | One-click automatic calibration with report generation. |
Automatic Verification | One-click automatic verification with report generation |
Manual Calibration | Select the calibration point (Voltage, Current) manually |
Manual Verification | Select the verification point (Voltage, Current) manually |
Customized Report | Customized Calibration Configuration with Automatic Deviation Analysis |
电池电压超过电压上限,确认时间 0.2 秒
- 使用万用表测量实际电池电压,并与 BTS 显示的电压进行比较,检查采样值是否一致。.
- 如果采样值和实际值不相等,则通过调换相邻通道的采样线来确认问题出在直流板还是线路上。如果布线有问题,请检查电压采样线的连接是否不正确、松动或不良。.
- 如果采样值和实际值相等,则检查上位机步进设置是否合理,并确定电池过压是在步进运行时发生还是在步进过程中的某个特定点发生。.
- 检查相应的电池是否有明显的肿胀、损坏或其他异常。如果有问题,请采取必要的安全措施。.
- 如果电池和电压采样线正常,则确认直流板故障并更换。.
电池电压低于电压下限,确认时间 0.2 秒
- 使用万用表测量实际电池电压,并与 BTS 显示的电压进行比较,检查采样值是否一致。.
- 如果采样值和实际值不相等,则通过调换相邻通道的采样线来确认问题出在直流板还是线路上。如果布线有问题,请检查电压采样线的连接是否不正确、松动或不良。.
- 如果采样值和实际值相等,则检查上位机步进设置是否合理,并确定电池欠压是在步进运行时发生还是在步进过程中的某个特定点发生。.
- 检查相应的电池是否有明显的肿胀、损坏或其他异常。如果有问题,请采取必要的安全措施。.
- 如果电池和电压采样线正常,则确认直流板故障并更换。.
模块 6S 未收到上位机数据,切换至故障状态。当模块从上位机接收到数据时,故障自动清除。.
- 检查模块和中间计算机是否处于正常通电状态。.
- 检查模块与中间计算机之间的 CAN 连接是否正常。.
- 检查 CANA 拨码开关是否设置正确。.
- 测量 CANA 总线上 CAN H 和 CAN L 之间的匹配电阻。应为 60±5 欧姆。如果不是,则调整信号适配器板上的匹配电阻。如果总线电压正常,则检查 BTS 故障记录,以确定是哪个子通道触发了故障。使用调试软件工具检查该通道显示的总线电压是否正常。如果不正常,则可确定 DC 板的总线采样出现故障,应更换该板。.
- 如果上述各点都正常,则连接 CAN 盒,利用捕获的信息确定问题出在中控电脑还是下控电脑。.
我们的产品
我们的电池测试设备包括各种专用测试系统,如毫安级测试系统、IT 电池测试系统和电动汽车电池测试系统等。









Multi-Functions DAQ
voltage accuracy: ±0.02%F.S.
voltage resolution: 0.1mV
acquisition rate: 10ms

High-Precision Automatic Calibration Unit
calibration time: ≤2 mins/CH
calibration accuracy: 0.0% F.S.
automatic calibration: one-click
让我们用创新创造未来。.